Full Cut Off VS Semi Cut Off

Aug 13, 2020

Leave a message

IESNA categorizes ‘cutoff ’ into four different classifications: Full Cutoff, Cutoff, Semi-Cutoff and

Non-Cutoff. 

Below are the definitions according to IESNA along with illustrations:

Full Cutoff - A luminaire light distribution with zero candela (intensity) at an angle of 90 degrees or above. Additionally, the candela per 1000 lamp lumens does not exceed 100 (10%) at a

vertical angle of 80 degrees.

Semi-Cutoff - A luminaire light distribution where the candela per 1000 lumens does not exceed 50 (5%) at an angle of 90 degrees or above. Additionally, the candela per 1000 lamp lumens does not exceed 200 (20%) at a vertical angle of 80 degrees.

Non-Cutoff - A luminaire light distribution where there is no candela restriction at any angle.